{"product_id":"solidcor-237-temperature-resistant-urethane-cement-slurry","title":"SolidCor 237 Temperature Resistant Urethane Cement Slurry","description":"\u003cp\u003eDymond SolidCor 237™ is a heavy-duty, bio-based urethane cement flooring system designed for demanding commercial and industrial environments. Its pourable slurry formulation delivers outstanding wear performance together with resistance to thermal shock, impact, abrasion and chemical exposure.\u003c\/p\u003e\n\n\u003cp\u003eSolidCor 237 can withstand higher heat exposure than typical unmodified urethanes and is particularly well suited to hot washdown areas. Recommended applications include commercial kitchens, food preparation areas, food and beverage facilities, restrooms and locker rooms.\u003c\/p\u003e\n\n\u003cp\u003eThe premeasured multi-component system is spread using a cam rake and backrolled with a spike roller. Aggregate or decorative flakes can then be broadcast into the wet slurry to create a durable, seamless and hygienic floor with no grout lines.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose SolidCor 237?\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eGood thermal shock resistance\u003c\/li\u003e\n\u003cli\u003eHeat resistance up to 200°F\u003c\/li\u003e\n\u003cli\u003eOutstanding wear performance\u003c\/li\u003e\n\u003cli\u003eResistance to impact and abrasion\u003c\/li\u003e\n\u003cli\u003eResistance to a range of chemical exposures\u003c\/li\u003e\n\u003cli\u003eSuitable for hot washdown areas\u003c\/li\u003e\n\u003cli\u003eSeamless, hygienic finish with no grout lines\u003c\/li\u003e\n\u003cli\u003eLow-odor, water-based formulation\u003c\/li\u003e\n\u003cli\u003eFast installation and fast cure\u003c\/li\u003e\n\u003cli\u003eNo primer normally required on properly prepared concrete\u003c\/li\u003e\n\u003cli\u003eSuitable for aggregate and decorative flake broadcast systems\u003c\/li\u003e\n\u003cli\u003eOptional topcoat depending on the required finish and system design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eRestaurant kitchens\u003c\/li\u003e\n\u003cli\u003eFood preparation areas\u003c\/li\u003e\n\u003cli\u003eFood processing facilities\u003c\/li\u003e\n\u003cli\u003eFood and beverage facilities\u003c\/li\u003e\n\u003cli\u003eBeverage production areas\u003c\/li\u003e\n\u003cli\u003eHot washdown areas\u003c\/li\u003e\n\u003cli\u003eRestrooms\u003c\/li\u003e\n\u003cli\u003eLocker rooms\u003c\/li\u003e\n\u003cli\u003eDemanding commercial and industrial floors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBuilt for Demanding Environments\u003c\/h2\u003e\n\n\u003cp\u003eSolidCor 237 is formulated for floors exposed to demanding operating conditions. Compared with typical unmodified urethanes, it can withstand higher heat exposure and provides good thermal shock capabilities, making it a suitable choice for hot washdown environments.\u003c\/p\u003e\n\n\u003cp\u003eThe system also withstands moderate impact, abrasion and chemical exposure. Its seamless construction eliminates grout lines where dirt and contaminants can collect, helping to create a durable and hygienic surface for commercial kitchens and food and beverage facilities.\u003c\/p\u003e\n\n\u003ch2\u003eChemical Resistance\u003c\/h2\u003e\n\n\u003cp\u003eSolidCor 237 has been tested against a range of food-related substances and industrial chemicals. Spot testing showed no physical damage from mustard, ketchup, lactic acid, vinegar or lemon juice.\u003c\/p\u003e\n\n\u003cp\u003eThe product also passed 24-hour immersion testing with 10% acetic acid, 30% nitric acid, 50% sodium hydroxide, 30% sulfuric acid and xylene. Chemical mixtures and exposure to chemicals at elevated temperatures should always be evaluated before installation.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\n\u003cp\u003eSolidCor 237 is normally installed directly onto properly prepared concrete without a primer. If concrete outgassing occurs during application, installation should be stopped and a suitable primer applied before continuing.\u003c\/p\u003e\n\n\u003cp\u003eImmediately after mixing, the pourable slurry is spread to the required thickness using a cam rake or other suitable equipment. It is then backrolled with a spike roller to settle the aggregate and reduce rake lines, followed by a loop or texture roller before broadcasting.\u003c\/p\u003e\n\n\u003cp\u003eAggregate or decorative flakes can be broadcast to rejection into the wet slurry. Once cured, the excess broadcast material is removed and the surface can be scraped before applying an optional topcoat to lock in the aggregate.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Highlights\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eApproximately 97% solids by weight when mixed with aggregate\u003c\/li\u003e\n\u003cli\u003eVOC content: 5 g\/L\u003c\/li\u003e\n\u003cli\u003eHeat resistance: Up to 200°F\u003c\/li\u003e\n\u003cli\u003eCompressive strength: 8,400 psi\u003c\/li\u003e\n\u003cli\u003eTensile strength: 1,050 psi\u003c\/li\u003e\n\u003cli\u003eFlexural strength: 2,700 psi\u003c\/li\u003e\n\u003cli\u003eBond strength: 100% concrete failure\u003c\/li\u003e\n\u003cli\u003eHardness: Shore D 80\u003c\/li\u003e\n\u003cli\u003eImpact resistance: 160 in.-lb.\u003c\/li\u003e\n\u003cli\u003eTypical finished thickness: 1\/8–3\/16 inch\u003c\/li\u003e\n\u003cli\u003eTypical coverage: 37–46 sq. ft. per kit at approximately 1\/8 inch\u003c\/li\u003e\n\u003cli\u003eWorking time: Approximately 15 minutes at 77°F\u003c\/li\u003e\n\u003cli\u003eLight foot traffic: Approximately 12 hours at 77°F\u003c\/li\u003e\n\u003cli\u003eHeavy foot traffic: Approximately 24 hours at 77°F\u003c\/li\u003e\n\u003cli\u003eFull cure: Approximately seven days at 77°F\u003c\/li\u003e\n\u003cli\u003eApplication temperature: 45–85°F\u003c\/li\u003e\n\u003cli\u003ePrimer: Normally not required\u003c\/li\u003e\n\u003cli\u003eTopcoat: Optional depending on the system requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eCan SolidCor 237 be installed in commercial kitchens?\u003c\/h3\u003e\n\n\u003cp\u003eYes. SolidCor 237 is recommended for commercial kitchens, food preparation areas and food and beverage facilities where a durable, seamless and shock-resistant floor is required.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I mix SolidCor 237 urethane cement slurry?\u003c\/h3\u003e\n\n\u003cp\u003eSolidCor 237 is supplied in premeasured kits and the complete kit should be mixed as supplied. Do not divide or modify the components.\u003c\/p\u003e\n\n\u003cp\u003ePour Part A into a clean five-gallon mixing pail. When using the separate dry pigment, add the complete pigment bag to Part A and mix for approximately 15 seconds using a low-speed drill and Jiffy-style mixing paddle. Add Part B and mix for a further 15 seconds.\u003c\/p\u003e\n\n\u003cp\u003eGradually add the complete bag of blended aggregate and continue mixing for approximately two minutes, or until all aggregate particles are thoroughly wetted and the mixture is uniform. Use slow-speed mixing equipment to avoid introducing excessive air.\u003c\/p\u003e\n\n\u003cp\u003eTransfer the mixed material into a second clean pail and remix before application. Apply the product immediately after mixing, as the working time is approximately 15 minutes at 77°F.\u003c\/p\u003e\n\n\u003ch3\u003eHow much area does one kit cover?\u003c\/h3\u003e\n\n\u003cp\u003eOne standard SolidCor 237 kit typically covers approximately 37–46 square feet at 1\/8-inch thickness. Actual coverage will vary depending on the concrete profile, application thickness, surface condition and complete system configuration.\u003c\/p\u003e\n\n\u003ch3\u003eCan SolidCor 237 handle heavy traffic?\u003c\/h3\u003e\n\n\u003cp\u003eSolidCor 237 is designed for demanding, high-wear commercial and industrial environments exposed to impact, abrasion and heavy use. It has a typical compressive strength of 8,400 psi, a Shore D hardness of approximately 80 and 100% concrete failure during bond-strength testing.\u003c\/p\u003e\n\n\u003cp\u003eAt 77°F, allow approximately 12 hours before light foot traffic, 24 hours before heavy foot traffic and seven days for full cure. Colder temperatures will increase the required cure time.\u003c\/p\u003e\n\n\u003ch3\u003eWhat surface preparation is required?\u003c\/h3\u003e\n\n\u003cp\u003eThe concrete must be structurally sound, dry and free from dirt, oil, laitance, coatings and other contaminants. Fine brush blasting or shot blasting is the preferred preparation method. The finished concrete should have an ICRI CSP 3–5 surface profile.\u003c\/p\u003e\n\n\u003cp\u003eRepair cracks, bug holes and other concrete imperfections before installation, and grind down raised projections. Do not apply SolidCor 237 over cracked or unsound concrete that has not been properly repaired.\u003c\/p\u003e\n\n\u003cp\u003eAnchoring keyways measuring at least 5\/16 inch wide by 5\/16 inch deep must be cut at terminations, joints, columns, doorways and drains to help prevent lifting and delamination.\u003c\/p\u003e\n\n\u003ch3\u003eDoes SolidCor 237 require a primer?\u003c\/h3\u003e\n\n\u003cp\u003eA primer is not normally required when SolidCor 237 is installed over properly prepared concrete. If concrete outgassing occurs, stop the installation and apply a suitable primer before continuing.\u003c\/p\u003e\n\n\u003ch3\u003eAt what thickness should SolidCor 237 be installed?\u003c\/h3\u003e\n\n\u003cp\u003eTypical finished installations range from approximately 1\/8 to 3\/16 inch, depending on the condition of the concrete, the broadcast material and the selected topcoat system. SolidCor 237 should not be feather-edged.\u003c\/p\u003e\n\n\u003ch3\u003eCan aggregate or decorative flakes be used?\u003c\/h3\u003e\n\n\u003cp\u003eYes. Aggregate or decorative flakes can be broadcast into the wet slurry. The surface should be broadcast until no wet areas remain. Once cured, remove the excess material and scrape the floor as required before applying an optional topcoat.\u003c\/p\u003e\n\n\u003ch3\u003eDoes SolidCor 237 require a topcoat?\u003c\/h3\u003e\n\n\u003cp\u003eA topcoat is optional and depends on the required finish and complete flooring system. When aggregate or decorative flakes are broadcast into the slurry, a suitable topcoat can be applied to lock the broadcast material into the surface.\u003c\/p\u003e\n\n\u003ch3\u003eHow much heat can SolidCor 237 withstand?\u003c\/h3\u003e\n\n\u003cp\u003eThe published heat resistance is up to 200°F. SolidCor 237 can withstand higher heat exposure than typical unmodified urethanes and has good thermal shock capabilities. However, high heat may discolor the surface, and chemical exposure at elevated temperatures should be evaluated before installation.\u003c\/p\u003e\n\n\u003ch2\u003eImportant Installation Considerations\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eDo not install over wet, cracked or unsound concrete.\u003c\/li\u003e\n\u003cli\u003eNew concrete must be cured for at least 15 days before application.\u003c\/li\u003e\n\u003cli\u003eThe substrate temperature must remain at least 5°F above the dew point.\u003c\/li\u003e\n\u003cli\u003eApply between 45°F and 85°F with relative humidity below 85%.\u003c\/li\u003e\n\u003cli\u003eMoisture vapor transmission must not exceed 12 lb per 1,000 sq. ft. over 24 hours.\u003c\/li\u003e\n\u003cli\u003eThe product is not UV or color stable and may discolor under high heat or certain lighting conditions.\u003c\/li\u003e\n\u003cli\u003eFloors should be sloped toward drains to prevent standing water and reduce slipping hazards.\u003c\/li\u003e\n\u003cli\u003eAlways install a suitable test area to confirm performance, appearance and compatibility before completing the entire project.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Dymond Coatings","offers":[{"title":"1 Unit (41 sqft) \/ Gray","offer_id":43697383637082,"sku":null,"price":249.41,"currency_code":"USD","in_stock":true},{"title":"1 Unit (41 sqft) \/ Tile Red","offer_id":43697383669850,"sku":null,"price":249.41,"currency_code":"USD","in_stock":true},{"title":"1 Unit (41 sqft) \/ Tan","offer_id":43697383702618,"sku":null,"price":249.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0651\/5982\/3450\/files\/dymond-coatings-solidcor-237-urethane-self-level-slurry-cement-manufacturing.webp?v=1784674894","url":"https:\/\/dymondcoatings.com\/products\/solidcor-237-temperature-resistant-urethane-cement-slurry","provider":"Dymond Coatings","version":"1.0","type":"link"}